Differential Pressure Transmitter

Differential Pressure Transmitter

Differential Pressure Transmitter – Description

Pressure transmitters are digital pressure transmitters featuring extensive user-friendliness and high accuracy. The
parameter assignment is performed using input buttons or the HART interface.
The comprehensive functionality makes for precise adjustment of the pressure transmitter to the requirements of the plant. Operation is very user-friendly in spite of the numerous setting options.
Due to their advanced diagnostic functionalities according to NAMUR NE107, the pressure transmitters are very
suitable for use in chemical plants. Thanks to the advanced diagnostic
functions and the process value storage, the  is “Ready
for Digitalization”.
The “Remote Safety Handling” function saves customers significant
amounts of time and money, because the SIL function can be
switched on and validated remotely via SIMATIC PDM. This eliminates
travel times and on-site operation via the local display or keyboard.
Parameter assignment using the HART protocol is very easy and quick
thanks to the innovative EDD with integrated Quick Start wizard.
The transmitters can be equipped with various types of remote
seals for special applications such as the measurement of highly
viscous substances.
pressure transmitters are available in various
versions for measuring:
• Gauge pressure
• Absolute pressure
• Differential pressure
• Level
• Volume flow
• Mass flow

  • Technical Data
  • Specification

A Differential Pressure (DP) Transmitter measures the difference in pressure between two points and converts it into a standardized electrical signal (typically 4–20 mA, HART, Foundation Fieldbus, etc.).

Typical Technical Data of a Differential Pressure Transmitter

Parameter Typical Specification
Measurement Type Differential Pressure
Measuring Range ±1 mbar to 40 bar DP (varies by model)
Output Signal 4–20 mA DC, HART, Fieldbus, Modbus
Supply Voltage 10.5–42 V DC (typical 24 V DC)
Accuracy ±0.05% to ±0.1% of span
Turndown Ratio Up to 100:1
Response Time 100–500 ms
Long-Term Stability ±0.1% URL per year or better
Process Connection 1/4″ NPT, 1/2″ NPT, Flanged Manifold
Wetted Materials SS316, Hastelloy, Monel, Tantalum (optional)
Housing Material Aluminum or Stainless Steel
Ambient Temperature −40°C to +85°C (typical)
Process Temperature −40°C to +120°C (with seals, higher possible)
Ingress Protection IP66/IP67 or IP68
Explosion Protection ATEX, IECEx, FM, CSA (model dependent)
Display Optional LCD/LED local display
Mounting Pipe, Wall, or Bracket Mounting
Zero & Span Adjustment Local buttons or remote configuration
Communication Protocol HART, Profibus PA, Foundation Fieldbus, WirelessHART

Common Applications

  • Flow measurement using orifice plates, venturi tubes, and flow nozzles
  • Filter monitoring
  • Tank level measurement
  • Boiler drum level measurement
  • HVAC air flow measurement
  • Clean room pressure monitoring
Parameter Typical Specification
Measured Variable Differential Pressure
Input Range 0–10 mbar to 0–250 bar (model dependent)
Accuracy ±0.05% to ±0.2% of span
Output Signal 4–20 mA, HART, Modbus, Fieldbus
Power Supply 12–45 V DC (commonly 24 V DC)
Process Connection 1/4″ NPT, 1/2″ NPT, flange mount (ANSI/DIN)
Wetted Material SS316L, Hastelloy (optional)
Enclosure Protection IP65 / IP67 / IP68 (model dependent)
Operating Temperature -40°C to +85°C (typical industrial range)
Mounting Type Direct mount / 3-valve manifold / remote seal
Communication Analog + Digital (HART common)
Applications Flow measurement, filter monitoring, level measurement, pressure drop monitoring